PROsine 1000 (120 Volt) Specifications

Specifications
Model Prosine 1000
Continuous output power 1000 W
Surge rating (5 seconds) 1500 W
Peak Output Current 25 A
Peak Efficiency 89%
No load draw, search mode <1.5 W
No load draw, idle mode <22 W
Output frequency 60Hz ±0.05%
Output waveform (resistive load) Sine Wave (<3% THD, 1% TYP.)
Input voltage range 10-16 VDC / 20-32 VDC
Output Voltage (at no load) 120 VAC RMS ±3%
Output Voltage
(over full load & battery voltage range)
120 VAC RMS +4%, -10%
Low Battery Cut-out 10 VDC / 20 VDC
High Battery Cut-out 16 VDC / 32 VDC
12Vdc/24Vdc models (5 sec. time delay, 10.5 VDC warning)
Protection Automatic overload, short circuit, over-temperature, over-voltage, under-voltage, reverse polarity (fuse), AC backfeed
Transfer Relay Rating 15 A (on hardwire/transfer relay models)
Transfer Time AC to Inverter Max. 2 cycles (typically 1 cycle)
Transfer Time Inverter to AC <2.5 seconds with POWERSAVE on
Regulatory Approvals CSA/NRTL Certified to CSA 107.1, UL 458 and UL 1741
Designed to meet ABYC E8, E9, A25, KKK-A-1822D available upon request
EMC FCC Class B
Dimensions (LxWxH) 15.4 x11.0 x4.5"
Weight 14.5 lbs
6.5 kg
Operating Temperature 0°C - 60°C, 32 F - 140 F
Storage Temperature -30°C - 70°C , -22°F - 158°F