Specifications |
|
Model |
PROsine 2.5
12-volt; (24-volt in parenthesis) |
|
Continuous output power / current |
2500 W / 21A
RMS |
|
Surge rating (5 seconds) |
4000 W |
|
Peak output current |
50 A |
|
Peak inverter efficiency |
89% |
|
No load current draw, in load sense mode |
<3 W |
|
Idle circuit adj. load sensing |
OFF, 10 W, 25
W, 50 W
[dip switches] |
|
No load current draw, inverter idle |
60 W |
|
Output frequency |
60 Hz ± 0.05%
(crystal controlled) |
|
Output waveform |
Sine wave
<5%THD |
|
Input voltage range |
10-16 VDC
(20-32Vdc) |
|
Output voltage (at no load) |
120 VAC RMS ±
3% |
|
Output voltage (over full load & battery voltage range) |
120 VAC RMS
-10% / +4% |
|
Low Battery Cut-out |
10 VDC, 10.5
VDC warning
(20 VDC, 21 VDC warning) |
|
High Battery Cut out |
16 VDC
(32Vdc) |
|
Protection |
Automatic
overload, short cir cuit, overtemperature
Reverse polarity (fuse) |
|
CHARGER |
|
Battery capacity selections |
50, 75, 100,
150, 200, 300, 400, 500, 600, 700, 800, 1000, 1200, 1400,
1700, >2000 Ah |
|
Charge Rate 12V (24V) |
100A (50A) |
|
Charger Power Factor Rating |
.99 |
|
Charger Efficiency |
> 80% |
|
Charge banks |
1 high
current |
|
Charge control |
3-stage with
manual equalize |
|
Temperature compensation |
3 settings or
optional sensor |
|
Electrolyte compensation |
flooded or
gel |
|
Input voltage range |
90-135 VAC |
|
AC service setting [max. cur rent draw] |
10 [8], 15
[12], 20 [16] , 30 [24] amps |
|
Transfer Relay rating |
30 A |
|
|
PROsine 2.5
12-volt, [24-volt] |
|
GENERAL |
|
Transfer Time Inverter to AC |
zero seconds,
[8 second delay] |
|
Transfer Time AC to Inverter (including detect time) |
20
milliseconds |
|
Regulatory Approvals |
CSA/NRTL
approved to CSA 107.1, UL 458 and UL 1741, FCC Class A |
|
Dimensions (L x W x H) |
20 x 15 x
5.5"
508 x 381 x 140 mm |
|
Weight |
32 lbs, 14.5
kg |
|
Operating Temperature Range (power derating above 25°C) |
0-60°C
Inverter mode, 0-50°C Charger mode |
|
Storage Temperature Range |
-30°C to 70°C |